skip to Main Content

Temprite Liquid Receivers are compatible with all refrigerants: carbon dioxide (CO2), hydrocarbons (HCs), including ethane, isobutane and propane, and ammonia (NH3)

Maximum Working Pressure: 41.4 bar (600 psi)
Part # Model Inlet / Outlet A
Dim.
B
Dim.
C
Dim.
D
Dim.
E
Dim.
F
Dim.
Internal
Volume
Code of
Construction
95210480 HR10-48 1-3/8″ ODS* Dia. Height Length Distance Between
Connections
Mounting
Bolt Center
FPT*
273 mm
10-3/4″
365 mm
14-3/8″
1219 mm
48″
838 mm
33″
305 mm
12″
1/2″ 61.97 liter
16.37 gal.
ASME
U

*FPT= Female Pipe Thread, ODS = Outside Diameter Solder

Pump Down Capacity
Model R22 R410A R134a R404A
HR10-48 64.8 kg
142.8 lb
56.9 kg
125.5 lb
65.7 kg
144.9 lb
56.2 kg
123.9 lb

All pump-down capacities are calculated using 90% of receiver volume at 90°F.

Temprite Customer or Technical Support: Contact Us.   