skip to Main Content

Temprite adds new vertical suction accumulators to its product lines for refrigeration systems. A suction accumulator is used to prevent a damaging overflow of liquid refrigerant and oil from going back to the compressor. It does this by metering the rate at which liquid refrigerant and oil are returned to the compressor, by heating the liquid to a gas. Each suction accumulator has one ODS inlet and one ODS outlet connection, and a threaded female pipe port.  The female port is for the customer to install an over-pressure safety-relief device of his choosing.

Suction Accumulators

Temprite Vertical Suction Accumulators accommodate nearly all refrigerants: (See chart)

The two smaller Vertical Suction Accumulators (Model’s SA4-10 and SA6-15) have a bottom mounting stud, and are UL listed. The two larger Vertical Suction Accumulators (Model’s SA8-20 and SA10-25) are designed, fabricated, and stamped per ASME Section VIII.  These two larger models are installed with fixed mounting feet.

Part # Model Inlet/
Outlet
A.
Relief Port
B.
Dia.
C.
Height
D.
Height of Cylinder
Internal
Volume
MAWP MDMT Code of
Constr.
96104100 SA4-10 7/8″ ODS* 1/8″ FPT* 102 mm
4″
281 mm
11-1/16″
254 mm
10″
1.84 L
.49 gal
44.8 bar @ 160°C
650 psig @ 320°F
0°C @ 44.8 bar
32°F @ 650 psig
UL
96106150 SA6-15 1-1/8″ ODS* 1/4″ FPT* 152 mm
6″
385 mm
15-1/8″
357 mm
14-1/16″
5.45 L
1.44 gal
44.8 bar @ 160°C
650 psig@ 320°F
0°C @ 44.8 bar
32°F @ 650 psig
UL
96108200 SA8-20 2-1/8″ ODS* 1/2″ FPT* 219 mm
8-5/8″
575 mm
22-5/8″
527 mm
20-3/4″
15.50 L
4.09 gal
41.4 bar @ 162.8°C
600 psig @ 325°F
-28.9°C @ 41.4 bar
-20°F @ 600 psig
ASME
UM
96110250 SA10-25 3-1/8″ ODS* 1/2″ FPT* 273 mm
10-3/4″
703 mm
27-11/16″
639 mm
25-1/8″
30.85 L
8.15 gal
41.4 bar @ 162.8°C
600 psig @ 325°F
-28.9°C @ 41.4 bar
-20°F @ 600 psig
ASME
UM

*FPT = Female Pipe Thread, ODS = Outside Diameter Solder

Pump Down Capacity
Model R22 R410A R134a R404A
SA4-10 1.9 kg
4.3 lb
1.7 kg
3.8 lb
2.0 kg
4.3 lb
1.7 kg
3.7 lbs
SA6-15 5.7 kg
12.6 lb
5.0 kg
11.1 lb
5.8 kg
12.7 lb
4.9 kg
10.9 lb
SA8-20 16.2 kg
35.7 lb
14.2 kg
31.4 lb
16.4 kg
36.2 lb
14.1 kg
31.1 lb
SA10-25 32.3 kg
71.1 lb
28.4 kg
62.7 lb
32.7 kg
72.1 lb
28.1 kg
61.9 lb

All pump-down capacities are calculated using 90% of receiver volume at 90°F.

Temprite Customer or Technical Support: Contact Us.   